                          Ref. PN 136                                Ref. PN 139
                          Aluminium Rebar Hook                       Aluminium Tower Hook


                           gm                                         gm
                           445                                        243






                            23kN                                       23kN


                           60mm                                       60mm






              Ref. No.    Material   Gate Opening  Minimum Breaking Strength   Finish Available       Conformity


              PN 136  Aluminium Alloy  60 mm              23 kN          Natural Silver/ Coloured, Anodized  EN 362:2004 Class T


              PN 139  Aluminium Alloy  60 mm              23 kN          Natural Silver/ Coloured, Anodized  EN 362:2004 Class T






                Tests Carried out on all types of CONNECTORS as per EN 362:2004




                                                                                              Gate Closed
                         Gate Closed & unlocked          Gate closed & locked


                             15 kN / 3 min                  20 kN / 3 min                  6 kN / 10 sec


                       The Karabiner must not Break  The Karabiner must not Break  After the test, the gate shall open like new one.
                                                                                         (Gate Function)



                                 Gate Closed                     Gate Closed
                                                                                   Gate Closed
                                                                                            1.5 kN / 60 sec

                             7 kN / 3 min                   1 kN / 90 sec
                                                                                After the test, the gate shall open like new one.
                                                                                     Gate Resistance (Gate Side)
                       The Karabiner must not Break  After the test, the gate shall open like the new one.
                            (Minor Axis)              Gate Resistance (Gate Face)






                                                                                           Call       Safety Expert