HORIZONTAL ANCHORAGE LINE
ANCHORAGE SYSTEMS ON RIGID CABLE LINE (ROOF MOUNTED)
EN 795 : 2012 TYPE C, ANSI Z 359.1-2007 & TS16415:2013 TYPE C
Horizontal Anchorage Lifeline System on
Rigid Cable Line
System Ref:
HORIZON PN 4000
(Roof Mounted)
Intermediate Brackets Orientation for different Installations
System Specifications :
Horizon PN 4000 provides permanent anchorage to 4 user who
have to constantly move along a horizontal track. It comprises of
a Stainless Steel Wire Rope (grade 316) of 5/16" diameter
running all along the horizontal track, and is installed at the ends Ceiling Mounting Floor Mounting Wall Mounting
using special End Extremity Posts. The Intermediate brackets
hold the wire in position all along the length of the wire, and are
installed at intervals of Maximum 50ft. The Wire Rope is
maintained in tension with the help to Tensioner at one end,
while the other end has a swageless termination on to the Eye of For Trapezoidal Sheet
the End Extremity Post.
The Stainless Steel Carriage body connects the user to the line
with the help of a Lanyard and moves smoothly without
interruption along the entire length of the Horizontal line and also
through the Intermediate Brackets, thus ensuring 100%
anchorage of the user at all times.
The line also has a Shock Absorber at one end which reduces
the impact of fall both on the user as well as on the extremities. Roof Top Anchor Post Roof Top Anchor Post
Extremity Intermediate
The system also has an Inspection Name Plate for identification, (Ref. SA07A) (Ref. SA07B)
traceability and maintenance of inspection records. One
Stainless Steel Cable tie is used to fasten the System Name For Standing Seam Sheet
Plate to the structure. At time of installation, the relevant details
are punched on the plate by a number punch. The revalidation
dates are punched each year on the plates after inspection and
revalidation.
The System is versatile and can be installed on Pre-engineered Building
Roofs, Fragile Roofs, Airports using the same components by using
appropriate posts to install the system to the client’s receiving structure.
Roof Top Anchor Post Roof Top Anchor Post
Extremity Intermediate
(Ref. SA07C) (Ref. SA07D)