FIXED ANCHORAGES








                                                              NEW     Corner Post

                                                                      Ref. PN 4000(26)

                                                                      Roof  top  Corner  post  is  designed  to  be  fixed  on
                                                                                                            0
                                                                                                        0
                                                                      galvolume/trapezoidal roof at the curve of 60 , 90 ,
            Ref. PN 4000(26) 60 0     Ref. PN 4000(26) 90 0           120  of horizontal lifeline installed on the roof.
                                                                         0
                                                                      The  base  plate  has  series  of  holes  to  fit  on
                                                                      galvolume/trapezoidal sheets of different pitch/rib








                       Ref. PN 4000(26) 120 0






                                                                                  NEW








           Ref. PN 4000(27) 60 0  Ref. PN 4000(27) 120 0                           0                         0
                                                                Ref. PN 4000(28) 60       Ref. PN 4000(28) 90
              NEW







                    Ref. PN 4000(27) 90 0                                   Ref. PN 4000(28) 120 0
          Corner Post                                           Corner Post
          Ref. PN 4000(27)                                      Ref. PN 4000(28)

          Standing Seam Roof top corner post is designed to be fixed   Standing Seam Roof top corner post is designed to be fixed on
                                                                                                         0
                                                                                                            0
                                                0
                                            0
                                                    0
          on standing seam roof top at the curve of 60 , 90 , 120  of   standing seam roof top as intermediate at the curve of 60 , 90 ,
                                                                  0
          horizontal lifeline installed on the roof.            120  of horizontal lifeline installed on the roof.
          The base plate has series of holes to fit on standing seam roof   The base plate has series of holes to fit on standing seam roof
          with different seam distance between 300 mm to 500 mm  with different seam distance between 300 mm to 600 mm
            Ref. No     Material       Finish          Weight       Min. Breaking Strength   Conforms to
                                                                                           EN795:2012 TYPE-C,
           PN 4000(26)  SS Grade 316  Electro Polished  3.86kgs             15kN
                                                                                             TS16415:2013
                                                                                           EN795:2012 TYPE-C
           PN 4000(27)  SS Grade 316  Electro Polished  4.0kgs              15kN
                                                                                             TS16415:2013
                                                                                           EN795:2012 TYPE-C
           PN 4000(28)  SS Grade 316  Electro Polished  4.26kgs             15kN
                                                                                             TS16415:2013

                                                                                                -19-